:: Volume 15, Issue 3 (autumn 2015) ::
J Ardabil Univ Med Sci 2015, 15(3): 330-338 Back to browse issues page
Determination of Serum Glucose Samples Using Biosensor Based on Copper Oxide Nanoparticles
A Shamsazar * , A Asadi , F Shamsazar
, Ali.shamsazar@yahoo.com
Abstract:   (7692 Views)

Background & Objectives: Maintain of fixed amount of glucose in blood has always been valuable. Especially in diabetic patients it is important to determine accurate amount of it. In this study we are trying to find a method to determination of the amount of serum glucose.

Methods: First a biosensor was prepared using carbon paste electrode modified with Copper Oxide nanoparticles for determination of serum glucose. The synthesized Copper Oxide nanoparticles were studied by using a variety of chemical spectrum UV-Vis, XRD, SEM and TEM. XRD confirmed that our synthesized are Copper Oxide nanoparticles. By measuring of the oxidation currents in the several levels of glucose, the accuracy and efficiency of biosensor was studied.

Results: Based on a increase of the electrocatalytic response of the oxidized form of GOD to dissolved oxygen, the proposed biosensor exhibits a linear response to glucose concentrations ranging from 0 to 15 mM with a detection limit (defined as the concentration that could be detected at the signal-to-noise ratio of 3) of 9 �M at an applied potential of 0.44 V which has better biosensing properties than those from other biosensors. This biosensor retained 89% of its initial response after 30 days storage at pH=7.

Conclusion: Carbon paste electrode and Copper Oxide nanoparticles offer excellent catalytic activity toward hydrogen peroxide generation in enzymatic reaction between glucose oxidase and glucose, which would enable sensitive determination of glucose. This biosensor exhibited good stability, reproducibility and low interferences. It has been used to diagnose diabetes very fast and sensitively and to determine the glucose concentrations in serum samples with satisfactory results.

Keywords: Biosensor, Copper Oxide Nanoparticles, Serum Glucose
Full-Text [PDF 286 kb]   (2879 Downloads)    
Type of Study: article |
Received: 2015/03/14 | Accepted: 2015/05/28 | Published: 2015/10/26
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shamsazar A, Asadi A, Shamsazar F. Determination of Serum Glucose Samples Using Biosensor Based on Copper Oxide Nanoparticles. J Ardabil Univ Med Sci 2015; 15 (3) :330-338
URL: http://jarums.arums.ac.ir/article-1-908-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 15, Issue 3 (autumn 2015) Back to browse issues page
مجله دانشگاه علوم پزشکی اردبیل Journal of Ardabil University of Medical Sciences
Persian site map - English site map - Created in 0.16 seconds with 40 queries by YEKTAWEB 4623